Table 1. Aging loss (%) and trimming loss (%) based on the aging temperatures and aging periods of dry-aged chicken breast subjected to the electric field supercooling system

Traits Temperature (°C) Dry-aging period (weeks)
1 2 3 4 5
Aging loss 0 25.08 ± 3.71Ac 44.93 ± 2.36Ab 56.01 ± 1.49Aa 57.00 ± 2.43Aa NA
−1 24.09 ± 2.09Ac 38.27 ± 1.46Bb 53.84 ± 3.59Aa 57.47 ± 4.96Aa 67.06 ± 2.68Aa
−2 12.98 ± 2.09Bc 27.27 ± 2.89Cb 36.42 ± 4.24Ba 47.18 ± 3.76Ba 50.64 ± 3.93Ba
Trimming loss 0 35.18 ± 5.68Ac 43.93 ± 4.20Ab 65.94 ± 4.00Aab 67.04 ± 8.35Aa NA
−1 30.69 ± 5.03Ac 44.49 ± 1.14Ab 69.35 ± 3.47Aa 69.20 ± 2.64Aa 72.85 ± 1.97Aa
−2 33.57 ± 4.68Ac 43.66 ± 1.39Ab 62.33 ± 4.73Ba 66.15 ± 3.24Aa 66.16 ± 4.02Ba
All values are mean ± SD.
Means in the same row with different numbers are significantly different (p < 0.05).
Means in the same column with different numbers are significantly different (p < 0.05).
NA, Not applicable.